InGround

InGround Standard Dielectric | DPD (Multi-Tube Single Armor Double Jacket Cable)

Applied in harsh environments with potential mechanical impact: in grounds of all the groups, bogs, unnavigable rivers.

1

Central strength member (fiberglass reinforced plastic)

2

Optical fiber

3

PBT loose tubes filled with water-swellable gel

4

Water-swellable gel

5

Inner jacket

4

Water-swellable gel

6

Fiberglass rods

7

Jacket

Reliable protection from serious mechanical impact

Perfect protection from rodents, suitable for duct installation

All-dielectric construction

Reduced weight, suitable for aerial installation

Allowable tensile strength up to 20 kN

Resistance to crushing loads up to 1 kN/сm

Allowable tensile strength 7 kN
Crush — from 0.4 kN/sm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 12.4 12.6 13.0 13.2 14.4 14.4 17.6
Cable weight, kg/km 136.1 139.1 147.9 151.1 179.6 179.6 292.9
Min bending radius, mm 186 189 195 198 216 216 264
Allowable tensile strength 16 kN
Crush — from 0.4 kN/sm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 14.6 14.8 15.2 15.4 16.2 16.2 17.6
Cable weight, kg/km 209.2 212.9 225.2 227.8 248.4 248.4 292.9
Min bending radius, mm 219 222 228 231 243 243 264
Allowable tensile strength 20 kN
Crush — from 0.4 kN/sm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable diameter, mm 15.6 15.8 16.2 16.4 17.0 17.0 17.6
Cable weight, kg/km 245.4 249.3 264.5 268.6 282.1 282.1 292.9
Min bending radius, mm 234 237 243 246 255 255 264
Start shopping
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -60°С…+70°С
Minimum bending radius 15x cable diameter
Life time 25 years
Warranty as specified in the supply agreement, min 2 years