InGround

InGround Standard | DPS (Multi-Tube Single Armor Double Jacket Cable)

Applied in harsh environments with potential mechanical impact: in grounds of all the groups, bogs, unnavigable rivers.

1

Central strength member (fiberglass reinforced plastic)

2

Optical fiber

3

PBT loose tubes filled with water-swellable gel

4

Water-swellable gel

5

Inner jacket

4

Water-swellable gel

6

Armor of zinc-coated steel wires

7

Jacket

Reliable protection from serious mechanical impact

Perfect protection from rodents, suitable for duct installation

The most popular design

Allowable tensile strength up to 80 kN (using rope wire)

Resistance to crushing loads up to 1 kN/сm

Allowable tensile strength 7 kN
Crush — from 0.4 kN/sm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96
Cable diameter, mm 12.4 12.6 13.0 13.2 14.2 14.2
Cable weight, kg/km 231.0 239.6 252.0 260.7 295.6 295.6
Min bending radius, mm 186 189 195 198 213 213
Allowable tensile strength 10 kN
Crush — from 0.4 kN/sm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96
Cable diameter, mm 12.4 12.6 13.0 13.2 14.2 14.2
Cable weight, kg/km 231.0 239.6 252.0 260.7 295.6 295.6
Min bending radius, mm 186 189 195 198 213 213
Allowable tensile strength 16, 20 kN
Crush — from 0.4 kN/sm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96
Cable diameter, mm 12.8 13.0 13.0 13.2 14.2 14.2
Cable weight, kg/km 249.5 252.7 252.0 260.7 295.6 295.6
Min bending radius, mm 192 195 195 198 213 213
Allowable tensile strength 40 kN
Crush — from 1 kN/sm
Fiber count up to 24 (6x4) up to 48 (6x8) up to 72 (6x12) up to 96 (6x16) up to 144 (6x24)
Cable diameter, mm 17.6 18.0 18.6 19.0 20.0
Cable weight, kg/km 521.5 545.5 576.1 601.0 650.1
Min bending radius, mm 264.0 270 279 285 300
Allowable tensile strength 80 kN
Crush — from 1 kN/sm
Fiber count up to 24 (6x4) up to 48 (6x8) up to 72 (6x12) up to 96 (6x16) up to 144 (6x24)
Cable diameter, mm 20.1 20.9 20.9 21.0 21.8
Cable weight, kg/km 825.6 883.6 883.6 886.7 936.5
Min bending radius, mm 301.5 313.5 313.5 315.0 327.0
Start shopping
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -60°С…+70°С
Minimum bending radius 15x cable diameter
Life time 25 years
Warranty as specified in the supply agreement, min 2 years