InGround

InGround Standard Reinforced | DPS2 (Multi-Tube Double Armor Double Jacket Cable)

Applied in harsh environments with potential mechanical impact: in all ground types, swamps and harsh rivers.

1

Central strength member (fiberglass reinforced plastic)

2

Optical fiber

3

PBT loose tubes filled with water-blocking gel

4

Water-blocking gel

5

Inner jacket

4

Water-blocking gel

6

Double armor of galvanized steel wires

7

Jacket

Suitable for harsh environment applications: in cryosolic grounds, on the bottom of navigable rivers and basins

Excellent rodent resistance, suitable for duct installation

Allowable tensile strength up to 80 kN (using rope wire)

Resistance to crushing load from 1 kN/сm

Max rated design tension 80 kN
Crush — from 1 kN/cm
Fiber count up to 24 up to 48 up to 72 up to 96 up to 144
Cable diameter, mm 19.6 20.0 20.8 21.2 23.2
Cable weight, kg/km 798.1 851.4 903.2 936.0 1189.1
Min bending radius, mm 294.0 300.0 312.0 318.0 348.0
Start shopping
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -60°С…+70°С
Minimum bending radius 15x cable diameter
Life time 25 years
Warranty as specified in the supply agreement, min 2 years