InTube

InTube Blowing Standard | microDPO (Multi-Tube Single Jacket Cable, Reduced Size)

Designed for duct installations Applied in duct, trays, blocks, tunnels, collecting channels, with no risk of rodents’ attacks.

1

Central strength member (dielectric fiberglass reinforced plastic)

4

Water-blocking yarns

2

Optical fiber

3

PBT loose tube filled with waterswellable gel

4

Water-blocking yarns

5

Jacket

All-dielectric construction

Dry construction is convenient in installation

Allowable tensile strength 0.3 - 1.5 kN

Up to 288 fibers

Allowable tensile strength 1,5 kN
Crush — from 0.1 kN/sm
Fiber count up to 72 up to 96 up to 144 up to 216 up to 288 up to 432
Cable diameter, mm 6.0 6.6 7.6 8.5 9.4 15.3
Cable weight, kg/km 24.4 28.7 36.4 42.0 58.0 141.1
Min bending radius, mm 90.0 99.0 114.0 127.5 141.0 229.5
Start shopping
Operation temperature -45°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -60°С…+70°С
Minimum bending radius 15x cable diameter
Life time 25 years
Warranty as specified in the supply agreement, min 2 years