ADSS

ADSS Aramid DJ

Aramid double jacket design for aerial installation on transmission towers, high-voltage power lines and railway catenary; highly resistant to electromagnetic effect

1

Central strength member (dielectric fiberglass reinforced plastic)

2

Optical fiber

3

PBT loose tubes filled with water-blocking gel

4

Water-blocking gel

5

Inner jacket

6

Reinforcing member – aramid yarns

7

Jacket

All-dieletric construction –fully resistant to electromagnetic fields

Wide range of operating temperatures. Installation temperature down to -30°C

The most reliable among InAir cables. Double tensile strength

Aerial installation on distribution and transmission lines up to 35 kV and above

For construction of communication lines between towns and cities with distances between towers reaching 500 meters

Maximum tensile load up to 100 kN

Max rated design tension 4 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.2 12.8 13.4 14.0
Cable weight, kg/km 115.3 126.1 137.3 147.9
Min bending radius, mm 183 192 201 210
Max rated design tension 6 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.2 12.8 13.4 14.0
Cable weight, kg/km 115.3 126.1 137.3 147.9
Min bending radius, mm 183 192 201 210
Max rated design tension 7 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.2 12.8 13.4 14.0
Cable weight, kg/km 116.3 126.1 137.3 147.9
Min bending radius, mm 183 192 201 210
Max rated design tension 8 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.3 12.8 13.4 14.0
Cable weight, kg/km 117.7 126.7 137.3 148.5
Min bending radius, mm 185 192 201 210
Max rated design tension 10 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.4 12.9 13.4 14.1
Cable weight, kg/km 120.3 129.4 138.3 151.8
Min bending radius, mm 186 194 201 212
Max rated design tension 12 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.5 13.0 13.5 14.2
Cable weight, kg/km 123.1 131.8 140.8 154.5
Min bending radius, mm 188 195 203 213
Max rated design tension 15 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.6 13.1 13.6 14.3
Cable weight, kg/km 127.5 135.8 144.4 159.1
Min bending radius, mm 189 197 204 215
Max rated design tension 20 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 13.2 13.6 13.8 14.9
Cable weight, kg/km 135.8 143.4 150.6 167.9
Min bending radius, mm 198 204 207 224
Max rated design tension 25 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 13.5 13.9 14.3 15.2
Cable weight, kg/km 143.0 150.5 158.4 176.0
Min bending radius, mm 203 209 215 228
Max rated design tension 30 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 13.8 14.2 14.6 15.6
Cable weight, kg/km 150.1 157.1 164.5 184.2
Min bending radius, mm 207 213 219 234
Max rated design tension 35 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 14.9 15.3 15.7 16.5
Cable weight, kg/km 170.7 180.1 189.4 206.8
Min bending radius, mm 223.5 229.5 235.5 247.5
Max rated design tension 40 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 15.2 15.6 16.0 16.8
Cable weight, kg/km 178.0 187.4 197.0 215.1
Min bending radius, mm 228.0 234.0 240.0 252.0
Start shopping
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С…+70°С
Minimum bending radius 15x cable diameter
Life time 25 years