ADSS

ADSS FiberGlass DJ

Fiberglass yarn double jacket design for aerial installation on transmission towers, high-voltage power lines and railway catenary; highly resistant to electromagnetic effect

1

Central strength member (dielectric fiberglass reinforced plastic)

2

Optical fiber

3

PBT loose tubes filled with water-blocking gel

4

Water-blocking gel

5

Inner jacket

6

Reinforcing member – fiberglass yarns

7

Jacket

All-dielectric construction – fully resistant to electromagnetic fields

Wide range of operating temperatures. Installation temperature down to -30°C

In duct applications fiberglass yarns protect the cable from rodents (medium protection level)

Cost-effective solution for city trunk lines

Aerial installation on distribution and transmission lines up to 35 kV

Application up to 15 kN with span lengths up to 300 meters

Max rated design tension 4 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.5 13.1 13.7 14.3
Cable weight, kg/km 121.8 133.7 144.9 156.5
Min bending radius, mm 187.5 196.5 205.5 214.5
Max rated design tension 6 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.5 13.1 13.7 14.3
Cable weight, kg/km 123.2 133.7 144.9 156.5
Min bending radius, mm 187.5 196.5 205.5 214.5
Max rated design tension 7 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.7 13.2 13.7 14.3
Cable weight, kg/km 127.3 136.4 144.9 156.5
Min bending radius, mm 190.5 198.0 205.5 214.5
Max rated design tension 8 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 12.8 13.3 13.8 14.5
Cable weight, kg/km 130.1 139.2 147.6 160.5
Min bending radius, mm 192.0 199.5 207.0 217.5
Max rated design tension 10 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (6х24)
Cable diameter, mm 13.1 13.6 14.0 14.7
Cable weight, kg/km 137.5 146.3 153.0 168.7
Min bending radius, mm 196.5 204.0 210.0 220.5
Max rated design tension 12 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (9х16)
Cable diameter, mm 13.3 13.8 14.3 15.0
Cable weight, kg/km 145.1 153.8 161.6 176.1
Min bending radius, mm 199.5 207.0 214.5 225.0
Max rated design tension 15 kN
Crush — 0.3 kN/cm
Fiber count up to 48 (6х8) up to 72 (6х12) up to 96 (6х16) up to 144 (9х16)
Cable diameter, mm 13.9 14.3 14.7 15.4
Cable weight, kg/km 157.2 164.2 172.0 187.8
Min bending radius, mm 208.5 214.5 220.5 231.0
Start shopping
Operation temperature -50°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С…+70°С
Minimum bending radius 15x cable diameter
Life time 25 years