ADSS

ADSS FiberGlass

Fiberglass yarn design for aerial installation on transmission towers, high-voltage power lines and railway catenary; highly resistant to electromagnetic effect

1

Central strength member (FRP rod)

4

Water-swellable yarns

2

Optical fiber

3

Gel-filled loose tube

4

Water-swellable yarns

5

Fiberglass yarns

6

Jacket

All-dielectric design

Reduced weight and size. Low ice and wind load

Dry design – easy to strip

Cost-effective design

Aerial Installation on distribution and transmission lines up to 35 kV

Application up to 10 kN with span lengths up to 200 meters

Wide range of operating temperatures. Installation temperature down to -30°C

Maximum rated design tension 2 kN
Crush — 0.22 kN/cm
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 9.0 10.3 13.1
Cable weight, kg/km 61.9 79.6 128.9
Minimum bending radius, mm 135 155 197
Maximum rated design tension 3 kN
Crush — 0.22 kN/cm
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 9.9 11.2 13.7
Cable weight, kg/km 76.3 95.9 141.4
Minimum bending radius, mm 149 168 206
Maximum rated design tension 4 kN
Crush — 0.22 kN/cm
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 11.7 13.7 17.2
Cable weight, kg/km 104.5 136.8 215.2
Minimum bending radius, mm 176 206 258
Maximum rated design tension 6 kN
Crush — 0.22 kN/cm
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 11.9 13.8 17.2
Cable weight, kg/km 108.7 140.9 215.2
Minimum bending radius, mm 179 207 258
Maximum rated design tension 8 kN
Crush — 0.22 kN/cm
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 12.2 14.1 17.4
Cable weight, kg/km 117.6 149.2 223.0
Minimum bending radius, mm 183 212 261
Maximum rated design tension 10 kN
Crush — 0.22 kN/cm
Fiber count, up to 72 (6х12) 96 (8х12) 144 (12х12)
Cable diameter, mm 12.6 14.4 17.7
Cable weight, kg/km 128.5 158.2 232.5
Minimum bending radius, mm 189 216 266

Get more detail by sending a request

Start shopping
Operating temperature* -50°С...+70 °С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С...+70 °С
Minimum bending radius 15x cable diameter
Life time 25 years

*-60°C…+70°C *upon request