Figure 8

Figure 8 CT GSW

Figure 8 Central Tube Galvanized Steel Wires

1

Optical fiber

2

PBT loose tube filled with water-blocking gel

3

Jacket

4

Steel wire

Reduced weight and size

Cost-effective design

Low installation cost

Max rated design tension 4 kN
Crush — 0.3 kN/cm
External strength member jacket diameter 5.0 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable jacket diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 12.2 12.3 12.5 12.7 13.0
Equivalent cable diameter, mm 7.8 7.9 8.0 8.2 8.5
Cable weight, kg/km 70.6 71.4 73.2 75.1 77.9
Max rated design tension 6 kN
Crush — 0.3 kN/cm
External strength member jacket diameter 5.6 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable jacket diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 12.8 12.9 13.1 13.3 13.6
Equivalent cable diameter, mm 8.0 8.1 8.3 8.5 8.7
Cable weight, kg/km 87.5 88.4 90.2 92.1 94.9
Max rated design tension 9 kN
Crush — 0.3 kN/cm
External strength member jacket diameter 6.2 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable jacket diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 13.4 13.5 13.7 13.9 14.2
Equivalent cable diameter, mm 8.3 8.4 8.5 8.7 9.0
Cable weight, kg/km 108.0 108.9 110.6 112.5 115.3
Max rated design tension 12 kN
Crush — 0.3 kN/cm
External strength member jacket diameter 6.8 mm
Fiber count up to 6 up to 8 up to 12 up to 16 up to 24
Cable jacket diameter, mm 6.2 6.3 6.5 6.7 7.0
Max overall cable size, mm 14.0 14.1 14.3 14.5 14.8
Equivalent cable diameter, mm 8.5 8.6 8.8 9.0 9.2
Cable weight, kg/km 131.9 132.8 134.6 136.4 139.2
Start shopping
Operation temperature -60°С…+70°С
Installation temperature -30°С…+50°С
Transportation and storage temperature -60°С…+70°С
Minimum bending radius 15x cable diameter
Life time 25 years