Figure 8

Figure 8 MT GSW

Figure 8 Multi-Tube Galvanized Steel Wires

1

Central strength member (FRP rod)

2

Optical fiber

3

Gel-filled loose tube

4

Water-blocking gel

5

Jacket

6

Steel wire

Affordable alternative to ADSS cable

Low installation cost

Maximum rated design tension 4 kN
Crush — 0.3 kN/cm
External strength member jacket diameter 5.2 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable jacket diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Maximum overall cable size, mm 15.8 16.1 16.5 17.0 17.6 18.6 21.0
Cable weight, kg/km 99.7 101.9 107.2 113.0 125.6 141.0 180.7
Maximum rated design tension 6 kN
Crush — 0.3 kN/cm
External strength member jacket diameter 5.8 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable jacket diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Maximum overall cable size, mm 16.4 16.7 17.1 17.6 18.2 19.2 21.6
Cable weight, kg/km 116.9 119.1 124.3 130.1 142.8 158.1 197.8
Maximum rated design tension 9 kN
Crush — 0.3 kN/cm
External strength member jacket diameter 6.4 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable jacket diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Maximum overall cable size, mm 17.0 17.3 17.7 18.2 18.8 19.8 22.2
Cable weight, kg/km 137.5 139.7 144.9 150.7 163.4 178.7 218.4
Maximum rated design tension 12 kN
Crush — 0.3 kN/cm
External strength member jacket diameter 7.0 mm
Fiber count up to 16 up to 32 up to 48 up to 64 up to 72 up to 96 up to 144
Cable jacket diameter, mm 8.6 8.9 9.3 9.8 10.4 11.4 13.8
Maximum overall cable size, mm 17.6 17.9 18.3 18.8 19.4 20.4 22.8
Cable weight, kg/km 161.6 163.8 169.0 174.8 187.5 202.8 242.5
Start shopping
Operating temperature -50°С...+70 °С
Installation temperature -30°С…+50°С
Transportation and storage temperature -50°С...+70 °С
Minimum bending radius 15x cable diameter
Life time 25 years