Indoor

Distribution MT


Application: installation into indoor/outdoor cable conduits and trays
1

Optical fiber

2

Micro tubes

3

Aramid yarns

4

Halogen-free flame-retardant jacket

5

Ripcord

All-dielectric design

High density of fibers makes it possible to bundle up to 24 fibers into micro loose tubes and place up to 48 micro loose tubes in a cable

Flame-retardant

UV-resistant

Indoor
Maximum operation tension, N 400
Maximum installation tension, N 800
Crush — 0.1 kN/cm
Fiber count up to 8 (2х4) up to 8 (4х2) up to 12 (2х6) up to 16 (4х4) up to 24 (6х4) up to 36 (6х6) up to 48 (8х6) up to 64 (16х4) up to 72 (12х6) up to 96 (16х6) up to 144 (24х6)
Cable diameter, mm 5.5 5.9 5.8 6.2 6.7 7.4 8.0 8.8 9.0 9.9 11.5
Cable weight, kg/km 30.7 34.7 33.4 37.2 43.0 49.1 55.7 66.6 67.8 78.9 99.2
Minimum bending radius, mm 55 59 58 62 67 74 80 88 90 99 115
Indoor and Outdoor
Maximum operation tension, N 800
Maximum installation tension, N 1600
Crush — 0.1 kN/cm
Fiber count up to 8 (2х4) up to 8 (4х2) up to 12 (2х6) up to 16 (4х4) up to 24 (6х4) up to 36 (6х6) up to 48 (8х6) up to 64 (16х4) up to 72 (12х6) up to 96 (16х6) up to 144 (24х6)
Cable diameter, mm 6.0 6.4 6.2 6.6 7.1 7.7 8.3 9.1 9.3 10.1 11.6
Cable weight, kg/km 35.5 39.1 38.0 41.4 46.8 52.6 59.0 69.6 70.7 81.6 101.6
Minimum bending radius, mm 60 64 62 66 71 77 83 91 93 101 116
Start shopping
Operating temperature -10°С…+50°С
Installation temperature -10°С…+50°С
Transportation and storage temperature -50°С…+50°С
Minimum bending radius 10x cable diameter
Life time 25 years