Blowing
Applied in tubes, ducts, trays, blocks, tunnels, collecting channels, with no risk of rodent attacks. Also applied for aerial installation between supports and buildings on external strength members or using the winding method.
Ducting
Applied in ducts, trays, blocks, tunnels, collecting channels, with a risk of rodent attacks.
Direct Buried
Applied in harsh environments with potential mechanical impact: in all ground types, swamps and harsh rivers.
Submarine
Applied in sea areas (coastal shelf and deep-sea), on navigable rivers, in lakes and water storage basins, in harsh environments, in bogs and unnavigable rivers.
Figure 8
Applied for aerial installations: on power lines, lamp posts, between buildings and constructions. Suitable for aerial installation on transmission equipment and power facilities in dielectric package.
Aerial
Applied for aerial installation on distribution and high voltage power lines, as well as railway catenary.
Indoor
Applied inside buildings (including vertical runs), in trays, channels, on outer sides of buildings, as well as in duct, in tubes and blocks. Suitable for blowing-in into protecting polyethylene tubes.
Drop
Applied for aerial installation on transmission towers, lamp posts, between buildings and constructions.
OPGW/Ground Wire
Applied in the construction of fiber-optic link on overhead transmission lines of 35 kV and more.
Fire Rated
Used for stationary installation when the optical fiber needs extra protection from mechanical damages.
Specialty Cable
For fiber optic monitoring systems.
Materials
Fiber type | U | G.655.D | G.654.E | ||||||
ITU-T recommendation | G.652.D / G.657.A1 | G.655.D | G.654.E | ||||||
Dimensional Specifications | |||||||||
Core-Clad Concentricity | 0.5 | – | 0.8 | ||||||
Cladding Diameter | 125±0.7 | 125±1.0 | 125±0.7 | ||||||
Cladding Non-Circularity | 0.7 | 0.6 | 2.0 | ||||||
Coating Diameter | 242±5 | 245±10 | 243.5±3.0 | ||||||
Transmission Specifications | |||||||||
Wavelength, nm | 1310 – 1625 | 1550 – 1625 | 1550 – 1625 | ||||||
Maximum Attenuation (dB/km) | |||||||||
1310 nm wavelength | 0.32 | – | – | ||||||
1383 nm wavelength | 0.32 | — | — | ||||||
1490 nm wavelength | — | — | — | ||||||
1550 nm wavelength | 0.18 | 0.22 | 0.17 | ||||||
1625 nm wavelength | 0.20 | 0.27 | 0.19 | ||||||
Dispersion ps/(nm*km) | |||||||||
1550 nm wavelength | 18 | 2…6 | 23 | ||||||
1625 nm wavelength | 22 | 4.5…11.2 | — | ||||||
Polarization Mode Dispersion (PMD), ps/√km | 0.2 | 0.2 | 0.1 | ||||||
Zero Dispersion | 0.092 | 0.084 | 0.084 | ||||||
Zero Dispersion Wavelength, nm | 1300…1324 | — | — | ||||||
Cable Cutoff Wavelength, nm | 1260 | — | 1530 | ||||||
Mode-Field Diameter, (μm) | |||||||||
1310 nm wavelength | 9.2±0.4 | — | — | ||||||
1550 nm wavelength | 10.4±0.5 | — | 10.8…13.2 | ||||||
Macrobend Loss, dB, λ=1550 nm/1625 nm | |||||||||
(1 turn х R16.0 mm), dB | — | 0.5/— | — | ||||||
(1 turn х R10.0 mm), dB | 0.75/1.5 | — | — | ||||||
(1 turn х R7.5mm), dB | — | — | — | ||||||
(1 turn х R5.0 mm), dB | — | — | — | ||||||
(100 turns х R30 mm), dB | — | —/0.05 | —/0.1 |
Fiber type | ОМ2 | ОМ3 | ОМ4 | ОМ5 | ОМ1 |
Standard | ITU-T G.651.1 | ITU-T G.651.1 | ITU-T G.651.1 | ITU-T G.651.1 | IEC 60793-2-10 |
Dimensional Specifications | |||||
Core Diameter | 50.0±2.5 | 50.0±2.5 | 50.0±2.5 | 50.0±2.5 | 62.5±3.0 |
Core-Clad Concentricity | 1.5 | ||||
Cladding Diameter | 125±1 | 125±1 | 125±1 | 125±1 | 125±2 |
Cladding Non-Circularity | 1 | ||||
Coating Diameter | 242±5 | ||||
Maximum Attenuation (dB/km) | |||||
850 nm wavelength | 2.3 | 2.3 | 2.3 | 2.3 | 2.9 |
953 nm wavelength | – | – | – | 1.7 | – |
1300 nm wavelength | 0.6 | ||||
Numerical Aperture | 0.200±0.015 | 0.200±0.015 | 0.200±0.015 | 0.200±0.015 | 0.275±0.015 |
Overfilled Bandwidth (MHz * km) | |||||
850 nm wavelength | 700 | 1500 | 3500 | 3500 | 200 |
953 nm wavelength | – | – | – | 1850 | – |
1300 nm wavelength | 500 | ||||
Effective Group Index of Retraction | |||||
850 nm wavelength | 1.482 | 1.482 | 1.482 | 1.482 | 1.496 |
1300 nm wavelength | 1.477 | 1.477 | 1.477 | 1.477 | 1.491 |
Attenuation to macrobending (2 turns on a bend former, radius of 15 mm), dB: | |||||
at a wavelength of 850 nm | 0.1 | 0.1 | 0.1 | 0.1 | – |
at a wavelength of 1300 nm | 0.3 | 0.3 | 0.3 | 0.3 | – |
Attenuation to macrobending (2 turns on a bend former, radius of 7.5 mm), dB: | |||||
at a wavelength of 850 nm | 0.2 | 0.2 | 0.2 | 0.2 | – |
at a wavelength of 1300 nm | 0.5 | 0.5 | 0.5 | 0.5 | – |